Vulnerability Snapshot
CVE-2017-7899 is rated CRITICAL โ exploitation is trivial or already observed in the wild and impact is severe. Patch immediately, not on the next maintenance window.
Affected technology: 1763-l16awa_series_a, 1763-l16awa_series_b, 1763-l16bbb_series_a, 1763-l16bbb_series_b, 1763-l16bwa_series_a, plus 5 other product variants.
Executive Summary
An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. User credentials are sent to the web server using the HTTP GET method, which may result in the credentials being logged. This could make user credentials available fo
Why It Matters
CVE-2017-7899 is rated CRITICAL severity, requiring immediate attention from security teams.
CVSS Base Score: 9.8/10
Affected Technologies
Vendors: rockwellautomation
Products: 1763-l16awa_series_a, 1763-l16awa_series_b, 1763-l16bbb_series_a, 1763-l16bbb_series_b, 1763-l16bwa_series_a, 1763-l16bwa_series_b, 1763-l16dwd_series_a, 1763-l16dwd_series_b, ab_micrologix_controller, 1766-l32awa_series_a, 1766-l32awa_series_b, 1766-l32awaa_series_a, 1766-l32awaa_series_b, 1766-l32bwa_series_a, 1766-l32bwa_series_b, 1766-l32bwaa_series_a, 1766-l32bwaa_series_b, 1766-l32bxb_series_a, 1766-l32bxb_series_b, 1766-l32bxba_series_a, 1766-l32bxba_series_b
๐ก๏ธWhat Defenders Should Check
Use Vulnios to continuously monitor your exposure to CVE-2017-7899 and similar vulnerabilities.
References & Sources
How Vulnios Detects This
Vulnios scans for this vulnerability using Trivy and Grype for SBOM-based CVE matching and Vulnios CVE feed continuous monitoring against your asset inventory. Run a scan against your environment to see whether you are exposed; findings are linked back to the original CVE record so triage starts with the patch path already known.
AI Security Advisor
Powered by Gemini
Get AI-powered security recommendations tailored to this specific threat โ including risk assessment, detection guidance, MITRE ATT&CK mapping, and actionable remediation steps.
Affected Products
Sources
Related Threat Alerts
- Critical Vulnerability: CVE-2017-7902 โ rockwellautomation โ 1763-l16awa_series_a, 1763-l16awa_series_b
- Critical Vulnerability: CVE-2017-7903 โ rockwellautomation โ 1763-l16awa_series_a, 1763-l16awa_series_b
- Critical Vulnerability: CVE-2017-7898 โ rockwellautomation โ 1763-l16awa_series_a, 1763-l16awa_series_b
- Critical Vulnerability: CVE-2016-9343 โ rockwellautomation โ softlogix_5800_controller_firmware, softlogix_5800_controller
Frequently Asked Questions
What is CVE-2017-7899?
CVE-2017-7899 is a critical-severity vulnerability tracked under the Common Vulnerabilities and Exposures program. An Information Exposure issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16
Am I affected?
Check whether your environment runs 1763-l16awa_series_a, 1763-l16awa_series_b, 1763-l16bbb_series_a, 1763-l16bbb_series_b, 1763-l16bwa_series_a. If you operate any of those, treat yourself as in scope until you have evidence otherwise. A Vulnios scan will identify the exact assets carrying the affected version.
How urgent is the response?
Critical: do not wait for your normal patch cycle. Verify exposure today, apply the vendor patch immediately, and add detection rules for any post-exploit indicators.
How do I remediate?
Apply the vendor patch listed in the upstream advisory linked under Sources. If the patch is not yet available, follow the vendor-supplied workaround (often a config flag or feature disable) and add detections for the published exploit pattern in your SIEM. Re-scan after the patch lands to confirm the finding clears.
Where can I track exploitation activity?
Watch CISA's Known Exploited Vulnerabilities catalog for CVE-2017-7899. Cross-reference with public exploit databases and your own SIEM/IDS for indicator-of-compromise patterns. Vulnios tracks KEV status automatically and surfaces it on the asset findings view.
How does Vulnios help with this?
Vulnios continuously cross-references your asset inventory against the live CVE feed (NVD, vendor advisories, CISA KEV, and curated OSINT). When a new CVE matches your environment, you get a prioritized finding with the severity, KEV status, exploit-prediction (EPSS), and a direct path to the vendor patch. You can start a free scan from the homepage.